Technical Info‎ > ‎

Technical Info - Probot 6000

Technical Data and Specification

Physical/Electrical

  • Size: 78.5"H, 70.0"W, 43.0"D (1994 x 1778 x 1092 mm)
  • Weight:1800 lbs. (817 kg)
  • Power: 120 VAC@10 A, or 220 VAC@5 A, 50/60 Hz
  • Temperature: 70° to 76°F, ambient (21° to 24°C)
  • Humidity: 40%-60% non condensing
  • Test Area: 18" x 18" (457.2 x 457.2 mm) or 12" x 12" (304.8 x 304.8 mm)

Computer

  • Pentium
  • Floppy drives: One 3.5" high-density & CD ROM drive
  • Hard Drive: 540 megabytes or larger
  • Operating System: Windows-compatible Test Software

Motion System

  • Number of Probes: 4 moving probes, 2 per side
  • X - Axis arms positioned by two linear motors, one on each end of arm.
  • Y- Axes arms driven by precision lead screws
  • Z-Axis Motion : Low mass probes driven by linear motor with rotary encoder
  • Accuracy ±0.0005" (12.7 µm)
  • Repeatability: 0.00035" (8.89 µm)
  • Resolution: X = 0.00003937" (1.0 µm) | Y = 0.00003937" (1.0 µm) | Z = 0.0005" (12.7 µm)
  • Pad Size / Pitch: Appropriate for 0.002" (50.8 µm) pads and 0.004" (101.6 µm) pitch
  • Speed: X=12" per second (304.8 mm per second)  Y= 16" per second (406.4 mm per second)
  • Optimized Motion: Software determines most efficient sequence of moves

 

Alignment / Calibration

  • Vision System  Automatic camera placement and pattern recognition

Probes

  • Probe tips: Blade-type
  • Other designs available

Standard Test Measurements

  • Overall Standard Voltage Range: Programmable from 0.5 to 500 VDC
  • Standard Resistance Range: Programmable from 1 ohms to 500 megohms
  • Standard Low Voltage Range: 0.5 to 100 VDC, adjustable in 0.5 volt steps
  • Standard High Voltage Range: 100 to 500 VDC, adjustable in 50 volt steps, 10 megohms to 500 megohms resistance
  • Standard Constant Current Mode: 8 to 500 milliamps current, adjustable in 2 milliamp steps, 1 to 1000 ohm resistance
  • High-speed Discharge™ Test: Measures discharge time of electrically charged nets and net segments (abnormal Test reading triggers resistance testing)
  • Fifth Probe: Stationary reference probe speeds discharge testing (all moving probes perform tests)

Test Options

  • Optional Low Voltage Ranges: 0.25 to 50 VDC, adjustable in 0.25 volt steps; 2.5 ohm to 50 megohms resistance
  • 1000 Volt Isolation Test: 100 to 1000 VDC, adjustable in 25 volt steps. 10 megohms to 500 megohms resistance
  • Embedded Resistor Testing: Measures discrete resistance values or ranges of embedded resistors, 1 ohm to 10 megohms
  • Kelvin Low Resistance Test: Provides 4-wire, high-accuracy low resistance measurements, 0.05 to 10 ohms

Hardware Options

  • Multiboard Hardware: Allows mounting of multiple boards in one setup
  • Loader/Unloader: Automated part handler
  • Part Carriers: Custom holders for arrays of parts Custom configurations are available.